A Indicator Gauge Data Source defines the source of string-based gauge data obtained from the monitor backend.

Parent Component
Relations to This Component
Properties
dsconfig Usage

Parent Component

The Indicator Gauge Data Source component inherits from the Gauge Data Source

Relations to This Component

The following components have a direct aggregation relation to Indicator Gauge Data Sources:

Properties

The properties supported by this managed object are as follows:


Basic Properties: Advanced Properties:
↓ description  None
↓ additional-text
↓ monitor-objectclass
↓ monitor-attribute
↓ include-filter
↓ resource-attribute
↓ resource-type
↓ minimum-update-interval

Basic Properties

description

Description
A description for this Gauge Data Source
Default Value
None
Allowed Values
A string
Multi-Valued
No
Required
No
Admin Action Required
None. Modification requires no further action

additional-text

Description
Additional information about the source of this data that is added to alerts sent as a result of gauges that use this Gauge Data Source. Information may include tips related to diagnosing alarms, caveats related to particular platforms or environments, and additional instructions useful for configuring gauges to use this Gauge Data Source.

The string may either be plain text or, to facilitate internationalization of text that appear in alarm and alert notification messages, a reference to a resource message declaration class and message descriptor, formatted as ${message.class.name:MESSAGE_DESCRIPTOR}.

Default Value
None
Allowed Values
A string
Multi-Valued
No
Required
No
Admin Action Required
None. Modification requires no further action

monitor-objectclass

Description
The object class name of the monitor entries to examine for generating gauge data.
Default Value
None
Allowed Values
The object class name of the monitor entries to examine for generating gauge data.
Multi-Valued
No
Required
Yes
Admin Action Required
None. Modification requires no further action

monitor-attribute

Description
Specifies the attribute on the monitor entries from which to derive the current gauge value. This attribute must appear in the entry specified by the object class.
Default Value
None
Allowed Values
An attribute of the specified monitor entry object class.
Multi-Valued
No
Required
Yes
Admin Action Required
None. Modification requires no further action

include-filter

Description
An optional LDAP filter that can be used restrict which monitor entries are used to compute output. If an LDAP filter is specified, only monitor entries that match the filter, in addition to including the object class specified by the monitor-objectclass property, will be included in the gauge data.
Default Value
None
Allowed Values
A valid LDAP search filter
Multi-Valued
No
Required
No
Admin Action Required
None. Modification requires no further action

resource-attribute

Description
Specifies the attribute whose value is used to identify the specific resource being monitored (e.g. device name). Gauges that represent data for multiple resources will provide monitor data in multiple monitor entries. This property specifies the attribute that is used to specifically identify the resource that is being monitored. A gauge that conveys information about disk devices for example would specify the attribute that contains the name of the devices in monitor entries.

When SNMP alerts are used to convey alarm status, this information will appear as part of the 'Specific Problems' field.

Default Value
cn
Allowed Values
An attribute of the specified monitor entry object class.
Multi-Valued
No
Required
No
Admin Action Required
None. Modification requires no further action

resource-type

Description
A string indicating the type of resource being monitored. The string should describe the type of object referred to by the resource attribute, and is intended to add clarity to resource name. For example a gauge for measuring the number of entries for each backend should have a label 'Backend'. If not defined, the resource will be generically be referred to as 'Resource'.

The string may either be plain text or, to facilitate internationalization of text that appears in alarm and alert notification messages, a reference to a resource message declaration class and message descriptor, formatted as ${message.class.name:MESSAGE_DESCRIPTOR}.

Default Value
None
Allowed Values
A string
Multi-Valued
No
Required
No
Admin Action Required
None. Modification requires no further action

minimum-update-interval (Read-Only)

Description
The minimum frequency with which gauges using this Gauge Data Source can be configured for update. In order to prevent undesirable side effects, some Gauge Data Sources may use this property to impose a higher bound on the update frequency of gauges.
Default Value
10 ms
Allowed Values
A duration. Lower limit is 10 milliseconds.
Multi-Valued
No
Required
No
Admin Action Required
None. Modification requires no further action


dsconfig Usage

To list the configured Gauge Data Sources:

dsconfig list-gauge-data-sources
     [--property {propertyName}] ...

To view the configuration for an existing Gauge Data Source:

dsconfig get-gauge-data-source-prop
     --source-name {name}
     [--tab-delimited]
     [--script-friendly]
     [--property {propertyName}] ...

To update the configuration for an existing Gauge Data Source:

dsconfig set-gauge-data-source-prop
     --source-name {name}
     (--set|--add|--remove) {propertyName}:{propertyValue}
     [(--set|--add|--remove) {propertyName}:{propertyValue}] ...

To create a new Indicator Gauge Data Source:

dsconfig create-gauge-data-source
     --source-name {name}
     --type indicator
     --set monitor-objectclass:{propertyValue}
     --set monitor-attribute:{propertyValue}
     [--set {propertyName}:{propertyValue}] ...

To delete an existing Gauge Data Source:

dsconfig delete-gauge-data-source